CGTFT - D-6550 DEVELOPER

  • MSDS: CGTFT
  • Manufacturer: TOSHIBA CORP
  • Product Name: D-6550 DEVELOPER
  • National Stock Number: 6850-00N084465
Product Identification

Product ID:D-6550 DEVELOPER
MSDS Date:04/09/1993
FSC:6850
NIIN:00N084465
MSDS Number: CGTFT

Responsible Party
TOSHIBA CORP
70 YANAGI-CHO, SAIWAI-KU
KAWASAKI-SHI 210, JAPAN

Emergency Phone: 044-548-5600

Info Phone: 044-548-5600

Preparer: TOSHIMICHI ISHIZAWA

Cage: S5342

Contractor
TOSHIBA CORP
KAWASAKI-SHI, JAPAN

Telephone: 044-548-5600

Cage: S5342

Ingredients

ACRYLIC ACID BUTYL ESTER POLYMER WITH STYRENE; (STYRENE

CAS: 25767-47-9

Fraction By Weight: 5.5%

OSHA PEL N/K

ACGIH TLV: N/K


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 0.5-1.5%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


IRON OXIDE

CAS: 1309-37-1

RTECS: NO7400000

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG(FE)/M3 FUME, B2


COPPER OXIDE

CAS: 1317-38-0

RTECS: GL7900000

OSHA PEL 1 MG CU/M3

ACGIH TLV: 1 MG CU/M3

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MINIMUM IRRITATION TO
RESPIRATORY TRACT MAY OCCUR AS WITH EXPOSURE TO ANY NON-TOXIC DUST.
Explanation of Carcinogenicity:CARBON BLACK: IARC MONOGRAPHS, VOLUME
65, PAGE 149, 1996: GROUP 2B. ANIMAL: LUNG.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:ACCUMULATIONO OF DUST IN THE
RESPIRATORY SYSTEM.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR IF EFFECTS OCCUR. CONSULT
LOCAL MEDICAL PERSONNEL. EYES: IMMEDIATELY FLUSH WITH WATER FOR AT
LEAST 15 MINUTES. INGESTION: RINSE MOUTH WITH WATER. CALL MD. SKIN:
FLUSH W ITH COPIOUS AMOUNTS OF WATER. SEE MD .

Fire Fighting

Flash Point:NONE
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM OR WATER.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:THIS MATERIAL HAS NO UNUSUAL FIRE OR
EXPLOSION HAZARDS.

Accidental Release

Spill Release Procedures:SWEEP UP OR CLEAN UP WITH A VACUUM CLEANER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NO SPECIAL STORAGE REQUIREMENTS FOR
SAFETY REASONS.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NONE REQUIRED UNDER NORMAL USE. USE NIOSH
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NONE REQUIRED UNDER NORMAL USE. EMERGENCY
EYEWASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA .
Work Hygienic Practices:INHALATION SHOULD BE AVOIDED.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:302F,150C
Spec Gravity:<0.8 (H*2O=1)
Solubility in Water:NEGLIGIBLE

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE, AND
NO*X.

Disposal

Waste Disposal Methods:WASTE MATERIAL MAY BE DUMPED OR INCINERATED
UNDER CONDITIONS WHICH MEET ALL FEDERAL, STATE AND LOCAL
ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.